1 X-Core Components. 2 Setup. 2.1 SETTING THE CURRENT DATE AND TIME. 2.2 SETTING A PROGRAM START TIME. 2.3 ELIMINATING A PROGRAM START TIME. 2.4 SETTING A STATION RUN TIME. 2.5 SETTING WATER DAYS. 2.6 SELECTING ODD OR EVEN DAYS TO WATER. 2.7 SELECTING INTERVAL WATERING.
When the X-Core receives an input from the sensor to disable . watering, the display will indicate those stations that have been . programmed to override the sensor. A station that is running in . the sensor override mode will flash the and icons alternately. Test program of all stations. The X-Core allows the user a simplified method for running a
Manual On/Off – Indicates when manual watering is programmed. Allows the user to activate the station manually. 12 . MV – Indicates that station one is set to master valve operation (only available on two-, four-, or six-station models) 13 . Battery Status – Indicates remaining battery life 14 .
the seasons without reprogramming the controller. Bars on the left allow quick visual reference to the seasonal adjustment percentage. 1 Manual-One Station Allows user to activate a one-time watering of a single valve System Off Allows user to discontinue all programs and watering. Also allows the user to set the programmable “rain off,” which
NoTE: One start time will activate all stations sequentially in that program. this eliminates the need to enter each station’s start time. Multiple start times in a program can be used for separate morning, afternoon, or evening watering cycles. start times may be entered in any order. the X-Core will automatically sort them.
If one or more station numbers are listed on the display, troubleshoot those stations. If there is no station number, troubleshoot the two-wire path connections. Open the controller inner door to see additional diagnostic information on the DUAL48M display. The display may show Line Open or Line Fault. The message may alternate with other screens.
MANUAL SINGLE STATION 1. Turn dial to Manual Single Station position. 2. Press to select station. Use + or – to set manual run time. 3. Turn dial to RUN position to begin immediately. MANUAL PROGRAM 1. Turn dial to RUN position. 2. Press and hold button for three seconds. 3. Press PRG to select program. 4. Release button for two seconds.
Page 1 X-CORE ® QUICK START GUIDE X-Core Irrigation Controller Programming Guide SCAN for help https:/ /hunter.help/XCore; Page 2: Table Of Contents ⑨ Odd/Even/Interval Days ③ Program Indicator ⑩ Active Water Day ④ Month Symbol ⑪ Non-Active Water Day ⑤ Run Time Symbol ⑫ Day of Week ⑥ Seasonal Adjust (%) ⑬ Rain Sensor Active/Bypass ⑦ Station Running ①Day Symbol https
Check AC power wiring. Electrical noise is entering the system. There is a fault in the wire to the pump start or master valve. There has been a fault with the wire leading to that station. SOLUTIONS. Only one start time per active program is required. Refer to “Setting Program Start. Times” on page 16.